Stations can be reset in different ways. Sometimes a reset is needde to bring a station back in a running automatic state after an error or warning occured. The following methods can be used. Some ways may require additional hardware or software.
- Control OFF / ON (resets all stations of the machine)
- Reset-Button inside a (Main-) Switch Cabined (resets all stations in direct / closer range)
- stop / start of the automatic mode (resets all stations that follow this operation mode, requires HMI Hardware or ZLS Software)
- reset stations using a ZLS ControlStation or the ZLS Webinterface (resets a single station, requires ZLS Software)